How does the attic drive the melt?
Warm air from the house rises into the attic, and where it finds gaps and thin insulation it heats the underside of the roof deck. Snow above a warm deck melts, and the water runs down toward the cold eave, where it can freeze into a dam.
The energy-efficiency program that Wisconsin homeowners are often referred to points to air leaks and low attic insulation as the two usual causes. A house can have both, and each makes the other worse, because a leaky ceiling drags warm, moist air into cold insulation that loses its loft as it dries and wets.
The melt is driven by the difference between the deck and the outdoor air. Closing that gap, by sealing the leaks and adding insulation, keeps the deck near the outdoor temperature. A deck at that temperature does not melt the snow above it in any meaningful amount, so the water that feeds a dam does not appear.
What does a working ventilation path look like?
A working path brings cool air in at the soffits, lets it move up along the underside of the sheathing and releases it at the ridge or the upper roof vents. The air carries off the moisture from the house and keeps the roof deck cold and dry.
The inlet has to be clear. Soffit vents are only useful if the insulation and the blown material have not covered them, and rafter baffles are the simplest way to keep a clear channel above the insulation at each bay. Without them, the top of the attic can warm while the eave stays blocked.
The outlet has to be matched to the inlet. A ridge vent running the full length of the roof gives a steady exit, while a few roof vents at random points can short-circuit the air. The technician balances the two so the air moves in one direction and does not simply cycle through the upper attic.
Is air sealing or ventilation the first job?
Air sealing comes first in most houses, because it cuts the moisture and heat load before the vents have to carry it. Adding ventilation to an attic that still leaks warm air mostly moves that air faster through the roof.
The usual order is to seal the ceiling plane at the penetrations, then bring insulation to depth, then confirm the soffit and ridge path works. Sealing at a stack or a light fixture is a small job, but it removes the largest single source of warm, moist air in many houses.
Once the leaks are closed, the vents do the work they were designed to do. The attic can then be checked on a cold morning. If frost forms in a thin, even layer that dries by midday, the balance is right. If frost builds into thick patches on the sheathing, the seal or the vent path needs another look.
Why does insulation depth matter at the eave?
The eave is the coldest part of the roof and the place where a dam forms, so the insulation at the outside walls decides whether the attic keeps the roof edge cold. A thin strip there lets heat flow out where the roof has least protection.
Insulation is often laid to a flat depth across the attic floor, but the heat loss through an exterior wall plate is higher than through the middle of the ceiling. Bringing the depth up at the perimeter, with baffles to hold the vent path open, is the detail that matters most for an ice-dam problem.
The right depth depends on the house, the existing material and the construction of the walls, and it cannot be decided from the outside. A measurement from the attic, not a guess, sets how much loft to add and whether the existing material should be replaced rather than topped up.